GFX CASE STUDY

Commercial Dishwasher

 
Application: Twenty gas water heaters (GWH) supply 150 degree F water @ 4 gpm to twenty flight-type, conveyor "dishwashers" used to remove mold release from injection molded plastic parts. Each parts washer requires an average of 2 GPM of 150 degree F water, 24 hours/day, 5 days/week.

Water Heater: Rheem Vanguard Model 6E743A, 199,900 Btu/hr input, 183 GPH @ 110 degree F rise, 170,000 Btu/hr output; 85% conversion efficiency .

Problem Eliminated By GFX: Heat exchanger fouling from mold release in drainwater.

Problem Reduced By GFX Model P3-60: Poor GWH recovery as supply water cools and they age.

 

Without GFX

68F Cold Supply 45F Cold Supply
Process Energy Demand: 19.68 Therm/day 25.20 Therm/day
GWH Load [See Notes] 19.68 Therm/day 25.20 Therm/day
Input Energy Demand: 23.15 Therm/day 29.65 Therm/day
Input Heat Demand @ 4gpm: 1.929 Therm/hr 2.471 Therm/hr
Drainwater Heat: 14.88 Therm/day 20.40 Therm/day

 

With GFX Model P3-60

Process Energy Demand: 19.68 Therm/day 25.20 Therm/day
Measured GFX-Performance: Drain - 39F drop [130/ 91] 53.6F drop
Coil - 39F rise [68/107] 53.6F rise
Measured Recycling Efficiency: 63% 63%
Heat Recovered: 9.36 Therm/day 12.85 Therm/day
GWH Load: 10.32 Therm/day 12.35 Therm/day
Input Energy Demand: 12.14 Therm/day 14.53 Therm/day
Input Heat Demand @ 4gpm: 1.012 Therm/hr 1.211 Therm/hr
Energy Savings: 47.6% 51.0%
Demand Savings: 47.6% 51.0%
Net Savings For 20 P3-60's: 48,672 Therm/yr 66,820 Therm/yr

NOTE 1: Distribution & Standby Loss Neglected
NOTE 2: 1 Therm = 100,000 Btu = 29.3 kWh
*GFX Measurements , Courtesy of Jason Blankenship, MERAMEC Group.

Return to GFX Home Page