Gravity Film Heat eXchanger (GFX) Models
Manufactured By Doucette Industries, Inc. York, PA
(Cross Reference Table To Doucette's Stock Numbers)
GFX* MODEL (.pdf) |
ULApp. |
DRAIN IN/OUT
|
COLD IN/OUT Type-L |
LOA |
DHR** EFF. |
PRESS DROP |
Ship Wgt(lbs) |
SAMPLE APPLICATIONS |
|
|
Yes |
3” & 3” |
1/2" |
60 |
60% |
8 |
49 |
Single Bathroom Homes Industrial Cooling-Walls Hydronic Heating |
|
Yes |
3” & 3” |
1/2" |
40 |
49% |
5 |
32 |
Restricted Height Location |
||
Yes |
3” & 3” |
1/2" |
30 |
41% |
4 |
24 |
” |
||
|
Yes |
4” & 4” |
1/2" |
60 |
67% |
11 |
64 |
Single Bathroom Homes Industrial Cooling-Walls Hydronic Heating |
|
Yes |
4” & 4” |
1/2" |
40 |
56% |
7 |
40 |
Restricted Height Location |
||
yes |
4” & 4” |
1/2" |
30 |
48% |
5 |
31 |
” |
||
|
Yes |
3” & 3” |
3/4" |
60 |
57% |
<2 |
49 |
Whole House Model Hi-Flo Pressure Drop 1/6th G3-60 |
|
Yes |
3” & 3” |
3/4" |
40 |
47% |
<2 |
32 |
Restricted Height Location |
||
Yes |
3” & 3” |
3/4" |
30 |
39% |
<2 |
24 |
” |
||
|
Yes |
4” & 4” |
3/4" |
60 |
62% |
<3 |
64 |
Whole House Model Hi-Flo Pressure Drop 1/6th G4-60 |
|
Yes |
4” & 4” |
3/4" |
40 |
53% |
<2 |
40 |
Restricted Height Location |
||
Yes |
4” & 4” |
3/4" |
30 |
46% |
<2 |
31 |
” |
||
|
NO |
2” & 3” |
3/4" |
601/8 |
74% |
<3 |
105 |
Commercial Dishwashers, Beauty Shops, Gang Showers, etc. |
|
NO |
2” & 3” |
3/4" |
461/4 |
64% |
<3 |
55 |
Restricted Height Location |
||
NO |
2” & 3” |
3/4" |
351/4 |
56% |
<2 |
49 |
” |
||
PS4-60 |
NO |
2” & 4” |
1" |
601/8 |
62% (4.5 gpm) |
<2 |
116 |
Two Manifolded S4-60 GFX's Hi-Flo Pressure Prop 1/6th P4-60 |
|
|
NO |
2” & 4” |
3/4" |
601/8 |
79% |
<4 |
111 |
Commercial Dishwashers, Beauty Shops, Gang Showers, etc. |
|
|
NO |
2” & 4” |
1" |
601/8 |
79% (4.5 gpm) |
<2 |
235 |
Two P3-60’s With 1 Drain & 2 Cold In/Out Water Manifolds |
|
|
Yes |
3” & 3” |
3/4" |
60 |
55% |
<2 |
53 |
3-coil Special For Troutdale Terrace Apartment Project |
|
|
Yes |
4” & 4” |
1” |
797/8 |
63, 52, 38% (2.25, 4.5 & 9 gpm) |
0.5, 1.2, 3.3 (2.25, 4.5 & 9 gpm) |
64 |
4-coil Special For New Jersey Apartment Project |
|
|
Yes |
2 |
1/2" |
20 |
49% |
<3.5 |
35 |
2-coil Special For Troutdale Terrace Project in Troutdale, OR |
|
|
Yes |
2 |
3/8" |
30 |
33% |
<9 |
15 |
Crawl Spaces, Single Shower, Under Sinks, Ice Machines, etc. |
|
Yes |
2 |
3/8" |
24 |
28% |
<7 |
12 |
” |
||
Yes |
2 |
3/8" |
20 |
24% |
<6 |
10 |
” |
||
|
NO |
2” (Type L) |
3/8” |
12 |
13.5%*** (1; >5 gpm) |
0.7 |
3 |
Tap heat off hot water recirc- loop to eliminate inline water |
|
|
NO |
1.5” (Type L) |
3/8” |
12 |
10.3%*** (1; >5 gpm) |
0.7 |
3 |
heaters & save water by providing instant hot water. |
|
Other Unlisted Models G4-48, G3-50, S4-65, G4-66-2, S3-74, S4-74 |
|
||||||||
Note: Coil & drain flow rates are 2.25 gpm unless specified otherwise.
* G Models - 1/2" Type-L coils on Type-DWV copper tube.
* S Models - two 1/2" Type-L coils manifolded on single Type-DWV copper tube.
* P Models - “G” or “S” models manifolded together.
** Nominal Drainwater Heat Recovery (DHR) Efficiency for balanced flow near 2.25 gallons per minute (gpm).
*** Nominal effectiveness for coil flow rate of 1 gpm and a flooded-tube flow-rate greater than 5 gpm.
Non-standard models having 3 or more coils on single 2", 3" or 4" copper or stainless tubing is available upon request.
List prices and models are subject to change without notice.